{"title":"Emtron ECUs","description":"","products":[{"product_id":"emtron-kv8","title":"EMtron KV8","description":"\u003cp\u003e\u003cspan\u003eEmtron’s KV8 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 8 Channels of fuel and 8 Channels fully sequential Ignition.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEvery KV8 is housed in a durable billet Aluminium enclosure and includes up to 64Mb permanent memory for on board logging and oscilloscope function, DBW control, twin Lambda controllers, twin digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e1.0 General\u003c\/h1\u003e\n\u003ch2\u003e \u003cstrong\u003ePower Supply\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eOperating Voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Current: 350mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection via External Fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” Battery Transient Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eECU Internal Temperature Operating Range: -30 to 110°C (-22 to 230°F)\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e Physical\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eExternal:\u003c\/h2\u003e\n\u003cp\u003eEnclosure Size: 134 mm x 162 mm x 27 mm\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight KV Series: 0.74kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInternal:\u003c\/h2\u003e\n\u003cp\u003eDual 100MHz Processors\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500MB DDR RAM  (0.5GB)\u003c\/li\u003e\n\u003cli\u003eUp to 64MB permanent memory storage for ECU logging and Oscilloscope Function\u003c\/li\u003e\n\u003cli\u003eUp to x10 channel Oscilloscope function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Sampling at 500k samples\/second\u003c\/p\u003e\n\u003cp\u003eo   Includes Crank and Cam sensors inputs\u003c\/p\u003e\n\u003cp\u003eo   Includes Digital Inputs 1-8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-Board Barometric Pressure Sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Range 40 - 115.0 kPa\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Axis Accelerometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   16 Bit Resolution\u003c\/p\u003e\n\u003cp\u003eo   2g\/ 4g\/ 8g dynamically selectable full-scale\u003c\/p\u003e\n\u003cp\u003eo   Output Data Rate 500Hz\u003c\/p\u003e\n\u003cp\u003eCommunications\u003c\/p\u003e\n\u003cp\u003eEthernet 100Mbps. High Speed communications channels used for tuning and uploading ECU log files.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x CAN nodes\/ 6 Channels per node\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569245\"\u003e\u003c\/a\u003e2.0 Injection\u003c\/h1\u003e\n\u003cp\u003eThe ECU can control both modes of injection: Saturated and Peak \u0026amp; Hold.\u003c\/p\u003e\n\u003cp\u003ePeak and Hold - 8 x channels \u003c\/p\u003e\n\u003cp\u003eWhen using low impedance injectors (\u0026lt; 5 Ohms) the ECU uses a switch mode current limiting technique to minimise heat dissipation in the Injector. This gives better injector control and helps maximize injector life by lower its operating temperature.\u003c\/p\u003e\n\u003cp\u003eIndependently configurable Peak and Hold currents up to 8 cylinders\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Peak current 8A\u003c\/li\u003e\n\u003cli\u003eMax Hold current 2A\u003c\/li\u003e\n\u003cli\u003eCurrent limited to 10A.\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSaturated\u003c\/p\u003e\n\u003cp\u003eRequired when injector resistance is greater than 5 Ohms.\u003c\/p\u003e\n\u003cp\u003eCurrent limited to 5A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eAuxiliary Fuel Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Fuel channels can be used to switch or modulate resistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 5A, current limit 8A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 60V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca name=\"_Toc356569246\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1\u003e3.0 Ignition\u003c\/h1\u003e\n\u003cp\u003eIgnition Control - 8x channels\u003c\/p\u003e\n\u003cp\u003e8 Channels Sequential\/Wasted Ignition or 4  Leading\/4 Trailing Ignition.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent switchable pull-up resistor control on channels 1 to 8.\u003c\/li\u003e\n\u003cli\u003eAdjustable source current;  35mA at 5V or  70mA  at 8.2V for high current mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAuxiliary Ignition Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Ignition channels can be used to switch or modulate\u003c\/p\u003e\n\u003cp\u003eresistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 1A, current limit 3.0A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 40V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569247\"\u003e\u003c\/a\u003e4.0 Digital Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDigital Inputs Overview - Up to 14x channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplication: Switch to 0V, Switch to VBatt, logic signal, Magnetic or Hall effect frequency based signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -20.0V\u003c\/li\u003e\n\u003cli\u003eInput Frequency Range: 0 - 30kHz (Available on DI 1- 8)\u003c\/li\u003e\n\u003cli\u003eFilter time constant = 12us\u003c\/li\u003e\n\u003cli\u003eInput Impedance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   DI 1- 8:  39k Ohms to ground.\u003c\/p\u003e\n\u003cp\u003eo   DI 9 -14: 70k Ohms to ground.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitchable Pull-up resistor on all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo    4k7 to 9.0V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eIndependent programmable arming thresholds from 0.1V to 15.0V on frequency based inputs. Resolution = 0.1V.\u003c\/li\u003e\n\u003cli\u003eProgrammable trigger edge(s).\u003c\/li\u003e\n\u003cli\u003eMaximum input signal amplitude \/-100V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Input Mode\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhen not used as frequency or switched inputs these channels can be used to measure analog signals. All Channels have over voltage protection.\u003c\/p\u003e\n\u003cp\u003e           \u003c\/p\u003e\n\u003cp\u003eDI 1- 8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e4.88mV resolution (10 bit effective resolution)\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 39k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDI 9- 14\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e20.0mV resolution\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 70k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569248\"\u003e\u003c\/a\u003e5.0 Auxiliary Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ECU contains 3 different types of auxiliary outputs. These drives are suitable for controlling relays, resistive and inductive loads, stepper motors, DC servo motors and electronic throttles.   Auxiliary channels 1-8  can be selected as Low or High Side Control on most models.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLow Side Driver - Up to 16x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-4:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 3A\u003c\/p\u003e\n\u003cp\u003eo    Modulated peak current 5A\u003c\/p\u003e\n\u003cp\u003eo   8A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 5-8:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 2A\u003c\/p\u003e\n\u003cp\u003eo   Modulated peak current 3.5A\u003c\/p\u003e\n\u003cp\u003eo   5A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 9-12: Half bride (see below)\u003c\/li\u003e\n\u003cli\u003eAuxiliary 13-14: Sink Continuous current 6A, 12A Limit\u003c\/li\u003e\n\u003cli\u003eAuxiliary 15-16: Sink Continuous current 10A, 20A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHigh Side Driver - Up to 8x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-8: Source Continuous current 4A, 9A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHalf Bridge Driver - 4x Channels (Aux 9 - 12)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSink or Source Continuous current 5A, 8A Limit.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp. Battery voltage through Aux 9-12 Supply pin.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569249\"\u003e\u003c\/a\u003e6.0 Analog Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll analog inputs are sampled using 12bit ADCs. They are suitable for sensors that have an output voltage, potentiometers and temperature sensors. All analog inputs can also be used as switched inputs with activation levels programmable from 0 - 5V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Inputs - Up to 14x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Temperature Inputs - Available on 6 channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable pull-up control on Analog Channels 7 -12\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e1.0k ohm input resistance to 5.0V and 100k Ohms to 0V\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569250\"\u003e\u003c\/a\u003e7.0 Crank and Cam Sensor Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo Independent channels with Magnetic, Hall effect and Logic options\u003c\/li\u003e\n\u003cli\u003eMaximum signal amplitude \/-100V\u003c\/li\u003e\n\u003cli\u003eInput Resistance = 39k Ohms to ground\u003c\/li\u003e\n\u003cli\u003eSwitchable Pull-up resistor = 4k7 Ohm to 5.0 V\u003c\/li\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eProgrammable Independent arming thresholds from 0.1V to 15.0V on all signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569251\"\u003e\u003c\/a\u003e8.0 Knock Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Independent channels.\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Digital Knock Integrated Circuit Technology\u003c\/li\u003e\n\u003cli\u003eSelectable Frequency from  5 - 15kHz\u003c\/li\u003e\n\u003cli\u003eSelectable Bandwidth form 300Hz - 5kHz\u003c\/li\u003e\n\u003cli\u003eProgrammable digital filter coefficients.\u003c\/li\u003e\n\u003cli\u003eSelectable gain control.\u003c\/li\u003e\n\u003cli\u003eBank selectable Knock Control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569252\"\u003e\u003c\/a\u003e9.0 Lambda Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 independent channels supporting Bosch LSU4.9 sensors\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Integrated circuit technology for sensor control.\u003c\/li\u003e\n\u003cli\u003eClosed Loop heater temperature control for precise lambda measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569253\"\u003e\u003c\/a\u003e10.0 Analog Voltage Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResolution is 4.88mV (10 bit)\u003c\/li\u003e\n\u003cli\u003eOutput voltage range 0 - 5.0V\u003c\/li\u003e\n\u003cli\u003eOutput driving current 100mA\u003c\/li\u003e\n\u003cli\u003eOutput impedance 22 Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569254\"\u003e\u003c\/a\u003e11.0 Voltage Supply Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Engine Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Auxiliary Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e8V CAS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.4 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569255\"\u003e\u003c\/a\u003e12.0 Voltage Supply Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eECU Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain ECU Power Supply\u003c\/li\u003e\n\u003cli\u003ePower Supply for Auxiliary Channels 1- 8 High Side Drivers\u003c\/li\u003e\n\u003cli\u003eOperating Range 6.0V - 22.0V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAux 9-12 Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply for Auxiliary 9-12 Half Bridge Drivers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Connect to ECU Power Supply in non DBW applications\u003c\/p\u003e\n\u003cp\u003eo   Connect to DBW Relay output in DBW applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFlyback Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback supply for Injector Channels when Peak \u0026amp; Hold mode is active\u003c\/li\u003e\n\u003cli\u003eFlyback supply for Auxiliary Channels.\u003c\/li\u003e\n\u003cli\u003eConnection will depend on loom layout. In most cases connect to a Battery Constant supply to prevent back-feeding issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569256\"\u003e\u003c\/a\u003e13.0 Dedicated Functions\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Main Relay Control\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a relay ground, 100mA Limit\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Ignition Switch\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsed to control Main EFI Relay circuit at key-on\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003eAdjustable ON\/OFF thresholds. Resolution = 0.1V.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":4833601978397,"sku":"1122-082","price":4400.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/EMTron_Australia_KV8.jpg?v=1527130539"},{"product_id":"emtron-kv12","title":"EMtron KV12","description":"\u003cp\u003e\u003ca href=\"https:\/\/emtronaustralia.com.au\/Files\/?dfilename=KV12++ECU+Data+Sheet+.pdf\" title=\"KV12 ECU Data Sheet\"\u003eKV12 ECU Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEmtron’s KV12 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 12 Channels of Fuel (6 cylinders fully sequential staged injection) and 12 Channels fully sequential Ignition. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Every KV12 is housed in a durable billet Aluminium enclosure and includes up to 64Mb permanent memory for on board logging and oscilloscope function, twin DBW control, twin Lambda controllers, twin digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e1.0 General\u003c\/h1\u003e\n\u003ch2\u003e \u003cstrong\u003ePower Supply\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eOperating Voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Current: 350mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection via External Fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” Battery Transient Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eECU Internal Temperature Operating Range: -30 to 110°C (-22 to 230°F)\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e Physical\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eExternal:\u003c\/h2\u003e\n\u003cp\u003eEnclosure Size: 134 mm x 162 mm x 27 mm\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight KV Series: 0.74kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInternal:\u003c\/h2\u003e\n\u003cp\u003eDual 100MHz Processors\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500MB DDR RAM  (0.5GB)\u003c\/li\u003e\n\u003cli\u003eUp to 64MB permanent memory storage for ECU logging and Oscilloscope Function\u003c\/li\u003e\n\u003cli\u003eUp to x10 channel Oscilloscope function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Sampling at 500k samples\/second\u003c\/p\u003e\n\u003cp\u003eo   Includes Crank and Cam sensors inputs\u003c\/p\u003e\n\u003cp\u003eo   Includes Digital Inputs 1-8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-Board Barometric Pressure Sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Range 40 - 115.0 kPa\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Axis Accelerometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   16 Bit Resolution\u003c\/p\u003e\n\u003cp\u003eo   2g\/ 4g\/ 8g dynamically selectable full-scale\u003c\/p\u003e\n\u003cp\u003eo   Output Data Rate 500Hz\u003c\/p\u003e\n\u003cp\u003eCommunications\u003c\/p\u003e\n\u003cp\u003eEthernet 100Mbps. High Speed communications channels used for tuning and uploading ECU log files.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x CAN nodes\/ 6 Channels per node\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569245\"\u003e\u003c\/a\u003e2.0 Injection\u003c\/h1\u003e\n\u003cp\u003eThe ECU can control both modes of injection: Saturated and Peak \u0026amp; Hold.\u003c\/p\u003e\n\u003cp\u003ePeak and Hold - 12 x channels \u003c\/p\u003e\n\u003cp\u003eWhen using low impedance injectors (\u0026lt; 5 Ohms) the ECU uses a switch mode current limiting technique to minimise heat dissipation in the Injector. This gives better injector control and helps maximize injector life by lower its operating temperature.\u003c\/p\u003e\n\u003cp\u003eIndependently configurable Peak and Hold currents up to 12 cylinders\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Peak current 8A\u003c\/li\u003e\n\u003cli\u003eMax Hold current 2A\u003c\/li\u003e\n\u003cli\u003eCurrent limited to 10A.\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSaturated\u003c\/p\u003e\n\u003cp\u003eRequired when injector resistance is greater than 5 Ohms.\u003c\/p\u003e\n\u003cp\u003eCurrent limited to 5A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eAuxiliary Fuel Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Fuel channels can be used to switch or modulate resistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 5A, current limit 8A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 60V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca name=\"_Toc356569246\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1\u003e3.0 Ignition\u003c\/h1\u003e\n\u003cp\u003eIgnition Control - 12x channels\u003c\/p\u003e\n\u003cp\u003e12 Channels Sequential\/Wasted Ignition or 6  Leading\/6 Trailing Ignition.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent switchable pull-up resistor control on channels 1 to 12.\u003c\/li\u003e\n\u003cli\u003eAdjustable source current;  35mA at 5V or  70mA  at 8.2V for high current mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAuxiliary Ignition Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Ignition channels can be used to switch or modulate\u003c\/p\u003e\n\u003cp\u003eresistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 1A, current limit 3.0A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 40V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569247\"\u003e\u003c\/a\u003e4.0 Digital Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDigital Inputs Overview - Up to 14x channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplication: Switch to 0V, Switch to VBatt, logic signal, Magnetic or Hall effect frequency based signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -20.0V\u003c\/li\u003e\n\u003cli\u003eInput Frequency Range: 0 - 30kHz (Available on DI 1- 8)\u003c\/li\u003e\n\u003cli\u003eFilter time constant = 12us\u003c\/li\u003e\n\u003cli\u003eInput Impedance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   DI 1- 8:  39k Ohms to ground.\u003c\/p\u003e\n\u003cp\u003eo   DI 9 -14: 70k Ohms to ground.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitchable Pull-up resistor on all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo    4k7 to 9.0V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eIndependent programmable arming thresholds from 0.1V to 15.0V on frequency based inputs. Resolution = 0.1V.\u003c\/li\u003e\n\u003cli\u003eProgrammable trigger edge(s).\u003c\/li\u003e\n\u003cli\u003eMaximum input signal amplitude \/-100V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Input Mode\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhen not used as frequency or switched inputs these channels can be used to measure analog signals. All Channels have over voltage protection.\u003c\/p\u003e\n\u003cp\u003e           \u003c\/p\u003e\n\u003cp\u003eDI 1- 8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e4.88mV resolution (10 bit effective resolution)\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 39k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDI 9- 14\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e20.0mV resolution\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 70k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569248\"\u003e\u003c\/a\u003e5.0 Auxiliary Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ECU contains 3 different types of auxiliary outputs. These drives are suitable for controlling relays, resistive and inductive loads, stepper motors, DC servo motors and electronic throttles.   Auxiliary channels 1-8  can be selected as Low or High Side Control on most models.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLow Side Driver - Up to 16x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-4:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 3A\u003c\/p\u003e\n\u003cp\u003eo    Modulated peak current 5A\u003c\/p\u003e\n\u003cp\u003eo   8A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 5-8:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 2A\u003c\/p\u003e\n\u003cp\u003eo   Modulated peak current 3.5A\u003c\/p\u003e\n\u003cp\u003eo   5A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 9-12: Half bride (see below)\u003c\/li\u003e\n\u003cli\u003eAuxiliary 13-14: Sink Continuous current 6A, 12A Limit\u003c\/li\u003e\n\u003cli\u003eAuxiliary 15-16: Sink Continuous current 10A, 20A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHigh Side Driver - Up to 8x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-8: Source Continuous current 4A, 9A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHalf Bridge Driver - 4x Channels (Aux 9 - 12)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSink or Source Continuous current 5A, 8A Limit.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp. Battery voltage through Aux 9-12 Supply pin.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569249\"\u003e\u003c\/a\u003e6.0 Analog Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll analog inputs are sampled using 12bit ADCs. They are suitable for sensors that have an output voltage, potentiometers and temperature sensors. All analog inputs can also be used as switched inputs with activation levels programmable from 0 - 5V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Inputs - Up to 14x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Temperature Inputs - Available on 6 channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable pull-up control on Analog Channels 7 -12\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e1.0k ohm input resistance to 5.0V and 100k Ohms to 0V\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569250\"\u003e\u003c\/a\u003e7.0 Crank and Cam Sensor Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo Independent channels with Magnetic, Hall effect and Logic options\u003c\/li\u003e\n\u003cli\u003eMaximum signal amplitude \/-100V\u003c\/li\u003e\n\u003cli\u003eInput Resistance = 39k Ohms to ground\u003c\/li\u003e\n\u003cli\u003eSwitchable Pull-up resistor = 4k7 Ohm to 5.0 V\u003c\/li\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eProgrammable Independent arming thresholds from 0.1V to 15.0V on all signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569251\"\u003e\u003c\/a\u003e8.0 Knock Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Independent channels.\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Digital Knock Integrated Circuit Technology\u003c\/li\u003e\n\u003cli\u003eSelectable Frequency from  5 - 15kHz\u003c\/li\u003e\n\u003cli\u003eSelectable Bandwidth form 300Hz - 5kHz\u003c\/li\u003e\n\u003cli\u003eProgrammable digital filter coefficients.\u003c\/li\u003e\n\u003cli\u003eSelectable gain control.\u003c\/li\u003e\n\u003cli\u003eBank selectable Knock Control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569252\"\u003e\u003c\/a\u003e9.0 Lambda Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 independent channels supporting Bosch LSU4.9 sensors\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Integrated circuit technology for sensor control.\u003c\/li\u003e\n\u003cli\u003eClosed Loop heater temperature control for precise lambda measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569253\"\u003e\u003c\/a\u003e10.0 Analog Voltage Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResolution is 4.88mV (10 bit)\u003c\/li\u003e\n\u003cli\u003eOutput voltage range 0 - 5.0V\u003c\/li\u003e\n\u003cli\u003eOutput driving current 100mA\u003c\/li\u003e\n\u003cli\u003eOutput impedance 22 Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569254\"\u003e\u003c\/a\u003e11.0 Voltage Supply Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Engine Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Auxiliary Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e8V CAS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.4 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569255\"\u003e\u003c\/a\u003e12.0 Voltage Supply Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eECU Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain ECU Power Supply\u003c\/li\u003e\n\u003cli\u003ePower Supply for Auxiliary Channels 1- 8 High Side Drivers\u003c\/li\u003e\n\u003cli\u003eOperating Range 6.0V - 22.0V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAux 9-12 Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply for Auxiliary 9-12 Half Bridge Drivers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Connect to ECU Power Supply in non DBW applications\u003c\/p\u003e\n\u003cp\u003eo   Connect to DBW Relay output in DBW applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFlyback Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback supply for Injector Channels when Peak \u0026amp; Hold mode is active\u003c\/li\u003e\n\u003cli\u003eFlyback supply for Auxiliary Channels.\u003c\/li\u003e\n\u003cli\u003eConnection will depend on loom layout. In most cases connect to a Battery Constant supply to prevent back-feeding issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569256\"\u003e\u003c\/a\u003e13.0 Dedicated Functions\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Main Relay Control\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a relay ground, 100mA Limit\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Ignition Switch\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsed to control Main EFI Relay circuit at key-on\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003eAdjustable ON\/OFF thresholds. Resolution = 0.1V.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":4836365336605,"sku":"1122-122","price":4950.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/EMTron_Australia_KV12.jpg?v=1527130528"},{"product_id":"emtron-kv16","title":"EMtron KV16","description":"\u003cp\u003e\u003cspan\u003eEmtron’s KV16 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 16 Channels of Fuel (8 cylinders fully sequential staged injection) and 12 Channels fully sequential Ignition.  Every KV16 is housed in a durable billet Aluminium enclosure and includes up to 32MB permanent memory for on board logging, 4-channel oscilloscope function, DBW control up to 4 channels, dual LSU4.9 Lambda controllers, dual digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003ePower Supply\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/li\u003e\n\u003cli\u003eOperating current: 400mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse battery protection via external fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” battery transient protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Temperature\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMax operating range: -30 to 110°C (-22 to 230°F)\u003c\/li\u003e\n\u003cli\u003eRecommended operating range: -30 to 85°C (-22 to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAluminium 6061 grade CNC billet enclosure\u003c\/li\u003e\n\u003cli\u003eEnclosure size 134 mm x 162 mm x 27 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 740g\u003c\/li\u003e\n\u003cli\u003eConnector system: 120-way Super Seal waterproof connectors with gold plated contacts, pin diameter of 1 mm\u003c\/li\u003e\n\u003cli\u003eCurrent rating: maximum 15A per pin (wire gauge dependant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInternal\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 100MHz processors\u003c\/li\u003e\n\u003cli\u003e500Mb DDR RAM\u003c\/li\u003e\n\u003cli\u003e32MB ECU logging memory, over 1200 channels available,  1Hz to 500Hz logging rate\u003c\/li\u003e\n\u003cli\u003e4-Channel oscilloscope function\n\u003cul\u003e\n\u003cli\u003eSampling at 100k samples\/second\u003c\/li\u003e\n\u003cli\u003eIncludes Crank and Cam sensor inputs\u003c\/li\u003e\n\u003cli\u003eIncludes Digital inputs 1-4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn-Board barometric pressure sensor, range 40 – 115.0 kPa\u003c\/li\u003e\n\u003cli\u003e3-Axis accelerometer, 16-Bit resolution, \u003cu\u003e+\u003c\/u\u003e2g\/\u003cu\u003e+\u003c\/u\u003e4g\/\u003cu\u003e+\u003c\/u\u003e8g dynamically selectable full-scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x High Speed Ethernet 100Mbps for tuning software connection\u003c\/li\u003e\n\u003cli\u003e2x CAN 2.0B 1Mbps\/ 6 Channels per node, total 128 messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":4837449531421,"sku":"1122-162","price":5610.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/EMTron_Australia_KV16.jpg?v=1527130534"},{"product_id":"kv16m-motorsport-ecu","title":"EMtron KV16M Motorsport ECU","description":"\u003cp\u003eBuilt on the race proven KV16 ECU Platform the \"M\" series provides additional flexibility and reliability through utilising the 136 Way Deutsch Autosport Connector System.\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"download-link\" href=\"https:\/\/emtron.world\/download\/2086\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\"\u003eKV16M ECU Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":21514309501033,"sku":"1122-16213","price":8250.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/KV16M.jpg?v=1549409531"},{"product_id":"emtron-sl8-ecu","title":"EMtron SL8 ECU","description":"\u003cp\u003eEmtron’s SL8 is a wire in ECU with extreme flexibility. This ECU will support up to 8 Channels of fully sequential Fuel and Ignition.  Every unit is housed in a durable billet Aluminium enclosure and includes 32MB permanent memory for on-board logging, 4-channel oscilloscope function, DBW control, Knock control up to 2 channels using digital filter technology, high speed Ethernet communications and 3-axis G-force sensing to name a few.\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"download-link\" href=\"https:\/\/emtron.world\/download\/2365\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\"\u003eSL8 ECU Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":21514358521961,"sku":"1912-082","price":2600.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/SL8-Front-Emtron.jpg?v=1549411205"},{"product_id":"emtron-sl4-ecu","title":"EMtron SL4 ECU","description":"\u003cp\u003eEmtron’s SL4 is a wire in ECU with extreme flexibility. This ECU will support up to 4 Channels of fully sequential Fuel and Ignition.  Every unit is housed in a durable billet Aluminium enclosure and includes 16MB permanent memory for on-board logging, 4-channel oscilloscope function, DBW control, Knock control using digital filter technology, high speed Ethernet communications and 3-axis G-force sensing to name a few.\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"download-link\" href=\"https:\/\/emtron.world\/download\/2354\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\"\u003eSL4 ECU Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"et_pb_toggle_content clearfix\" style=\"display: block;\"\u003e\n\u003cp\u003eEmtron’s comprehensive Emtune tuning software is used to connect to the ECU.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicrosoft Windows \u003csup\u003e \u003c\/sup\u003e7 -10 compatible\u003c\/li\u003e\n\u003cli\u003eFree licence\u003c\/li\u003e\n\u003cli\u003eMemory requirements: 0.5GB RAM\u003c\/li\u003e\n\u003cli\u003eECU connection using Ethernet, IPV4 protocol\u003c\/li\u003e\n\u003cli\u003eTuning and data analysis\u003c\/li\u003e\n\u003cli\u003ePC and ECU data logging\u003c\/li\u003e\n\u003cli\u003eLive pause and data playback\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning functions\u003c\/li\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eOscilloscope display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":21514365730921,"sku":"1912-042","price":2400.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/SL4-Front-EMtron.jpg?v=1549411492"},{"product_id":"sl-series-ab-connector-kit","title":"SL Series AB Connector Kit","description":"Plug and pin set for the EMtron SL Series ECU, includes communications cable.","brand":"Emtron","offers":[{"title":"Default Title","offer_id":21514378543209,"sku":"","price":154.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/SL_Series_AB_Connector_Kit.jpg?v=1549411915"},{"product_id":"emtron-sl6-ecu","title":"EMtron SL6 ECU","description":"\u003cp\u003eEmtron’s SL6 is a wire in ECU with extreme flexibility. This ECU will support up to 6 Channels of fully sequential Fuel and Ignition. Every unit is housed in a durable billet Aluminium enclosure and includes 32MB permanent memory for on-board logging, 4-channel oscilloscope function, DBW control, Knock control up to 2 channels using digital filter technology, high speed Ethernet communications and 3-axis G-force sensing to name a few.\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"download-link\" href=\"https:\/\/emtron.world\/download\/2365\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\"\u003eSL6 ECU Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":32228620861545,"sku":"1912-082-1","price":2500.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/sl6-front-photoshop-resize.jpg?v=1587432897"},{"product_id":"evo-iv-viii-plugin-ecu","title":"EVO IV-VIII Plugin ECU","description":"\u003cp\u003e“Our Plugin ECU Series merges the extreme power of our race proven KV series ECU with the convenience of connecting directly into the factory vehicle connector system”\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch2\u003eECU Overview\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e6061 Aluminium CNC Billet Enclosure\u003c\/li\u003e\n\u003cli\u003eDual 100MHz Processors\u003c\/li\u003e\n\u003cli\u003e32MB ECU Logging (Over 600 Channels)\u003c\/li\u003e\n\u003cli\u003eEthernet High Speed Communications\u003c\/li\u003e\n\u003cli\u003eUp to 4 Ignition Outputs (Re assign factory pins)\u003c\/li\u003e\n\u003cli\u003eDBW Control (Re assign factory pins)\u003c\/li\u003e\n\u003cli\u003e3 Axis Accelerometer\u003c\/li\u003e\n\u003cli\u003e1 x CAN Bus (Expansion Connector)\u003c\/li\u003e\n\u003cli\u003e1 x Individual Cylinder Knock Control Input (Bosch)\u003c\/li\u003e\n\u003cli\u003eUpgradable to run the Emtron Fuel model through installation of a Flex Meter, Fuel Temperature and Fuel Pressure Sensor\u003c\/li\u003e\n\u003cli\u003eCompatible with all Emtron Motorsport features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":37577563275461,"sku":"1609-52248","price":4400.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/products\/7550ac9bf3074146984295b19af51034-1.jpg?v=1605748599"},{"product_id":"emtron-kv16-and-install-kit","title":"EMTRON KV16 AND INSTALL KIT","description":"\u003cp\u003e\u003cstrong\u003eThis package is ideal for those building a new harness or re-pinning a new harness to suit the Emtron ECU.  The Kit includes an Emtron KV16, ABCD Plug and Pin Kit, Tuning Cable and Billet KV Mount.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEmtron’s KV16 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 16 Channels of Fuel (8 cylinders fully sequential staged injection) and 12 Channels fully sequential Ignition.  Every KV16 is housed in a durable billet Aluminium enclosure and includes up to 32MB permanent memory for on board logging, 4-channel oscilloscope function, DBW control up to 4 channels, dual LSU4.9 Lambda controllers, dual digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003ePower Supply\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/li\u003e\n\u003cli\u003eOperating current: 400mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse battery protection via external fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” battery transient protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Temperature\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMax operating range: -30 to 110°C (-22 to 230°F)\u003c\/li\u003e\n\u003cli\u003eRecommended operating range: -30 to 85°C (-22 to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAluminium 6061 grade CNC billet enclosure\u003c\/li\u003e\n\u003cli\u003eEnclosure size 134 mm x 162 mm x 27 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 740g\u003c\/li\u003e\n\u003cli\u003eConnector system: 120-way Super Seal waterproof connectors with gold plated contacts, pin diameter of 1 mm\u003c\/li\u003e\n\u003cli\u003eCurrent rating: maximum 15A per pin (wire gauge dependant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInternal\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 100MHz processors\u003c\/li\u003e\n\u003cli\u003e500Mb DDR RAM\u003c\/li\u003e\n\u003cli\u003e32MB ECU logging memory, over 1200 channels available,  1Hz to 500Hz logging rate\u003c\/li\u003e\n\u003cli\u003e4-Channel oscilloscope function\n\u003cul\u003e\n\u003cli\u003eSampling at 100k samples\/second\u003c\/li\u003e\n\u003cli\u003eIncludes Crank and Cam sensor inputs\u003c\/li\u003e\n\u003cli\u003eIncludes Digital inputs 1-4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn-Board barometric pressure sensor, range 40 – 115.0 kPa\u003c\/li\u003e\n\u003cli\u003e3-Axis accelerometer, 16-Bit resolution, \u003cu\u003e+\u003c\/u\u003e2g\/\u003cu\u003e+\u003c\/u\u003e4g\/\u003cu\u003e+\u003c\/u\u003e8g dynamically selectable full-scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x High Speed Ethernet 100Mbps for tuning software connection\u003c\/li\u003e\n\u003cli\u003e2x CAN 2.0B 1Mbps\/ 6 Channels per node, total 128 messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":42470863470789,"sku":"45985864384829","price":5995.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/EMTron_Australia_KV16_bfff836f-9bf9-4aed-89b1-d25347c2f8b8.jpg?v=1698715453"},{"product_id":"emtron-kv8-1","title":"EMTRON KV8 AND 8 BUTTON KEYPAD","description":"\u003cp\u003e\u003cspan\u003eEmtron’s KV8 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 8 Channels of fuel and 8 Channels fully sequential Ignition.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEvery KV8 is housed in a durable billet Aluminium enclosure and includes up to 64Mb permanent memory for on board logging and oscilloscope function, DBW control, twin Lambda controllers, twin digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e1.0 General\u003c\/h1\u003e\n\u003ch2\u003e \u003cstrong\u003ePower Supply\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eOperating Voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Current: 350mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection via External Fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” Battery Transient Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eECU Internal Temperature Operating Range: -30 to 110°C (-22 to 230°F)\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e Physical\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eExternal:\u003c\/h2\u003e\n\u003cp\u003eEnclosure Size: 134 mm x 162 mm x 27 mm\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight KV Series: 0.74kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInternal:\u003c\/h2\u003e\n\u003cp\u003eDual 100MHz Processors\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500MB DDR RAM  (0.5GB)\u003c\/li\u003e\n\u003cli\u003eUp to 64MB permanent memory storage for ECU logging and Oscilloscope Function\u003c\/li\u003e\n\u003cli\u003eUp to x10 channel Oscilloscope function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Sampling at 500k samples\/second\u003c\/p\u003e\n\u003cp\u003eo   Includes Crank and Cam sensors inputs\u003c\/p\u003e\n\u003cp\u003eo   Includes Digital Inputs 1-8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-Board Barometric Pressure Sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Range 40 - 115.0 kPa\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Axis Accelerometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   16 Bit Resolution\u003c\/p\u003e\n\u003cp\u003eo   2g\/ 4g\/ 8g dynamically selectable full-scale\u003c\/p\u003e\n\u003cp\u003eo   Output Data Rate 500Hz\u003c\/p\u003e\n\u003cp\u003eCommunications\u003c\/p\u003e\n\u003cp\u003eEthernet 100Mbps. High Speed communications channels used for tuning and uploading ECU log files.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x CAN nodes\/ 6 Channels per node\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569245\"\u003e\u003c\/a\u003e2.0 Injection\u003c\/h1\u003e\n\u003cp\u003eThe ECU can control both modes of injection: Saturated and Peak \u0026amp; Hold.\u003c\/p\u003e\n\u003cp\u003ePeak and Hold - 8 x channels \u003c\/p\u003e\n\u003cp\u003eWhen using low impedance injectors (\u0026lt; 5 Ohms) the ECU uses a switch mode current limiting technique to minimise heat dissipation in the Injector. This gives better injector control and helps maximize injector life by lower its operating temperature.\u003c\/p\u003e\n\u003cp\u003eIndependently configurable Peak and Hold currents up to 8 cylinders\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Peak current 8A\u003c\/li\u003e\n\u003cli\u003eMax Hold current 2A\u003c\/li\u003e\n\u003cli\u003eCurrent limited to 10A.\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSaturated\u003c\/p\u003e\n\u003cp\u003eRequired when injector resistance is greater than 5 Ohms.\u003c\/p\u003e\n\u003cp\u003eCurrent limited to 5A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eAuxiliary Fuel Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Fuel channels can be used to switch or modulate resistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 5A, current limit 8A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 60V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca name=\"_Toc356569246\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1\u003e3.0 Ignition\u003c\/h1\u003e\n\u003cp\u003eIgnition Control - 8x channels\u003c\/p\u003e\n\u003cp\u003e8 Channels Sequential\/Wasted Ignition or 4  Leading\/4 Trailing Ignition.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent switchable pull-up resistor control on channels 1 to 8.\u003c\/li\u003e\n\u003cli\u003eAdjustable source current;  35mA at 5V or  70mA  at 8.2V for high current mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAuxiliary Ignition Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Ignition channels can be used to switch or modulate\u003c\/p\u003e\n\u003cp\u003eresistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 1A, current limit 3.0A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 40V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569247\"\u003e\u003c\/a\u003e4.0 Digital Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDigital Inputs Overview - Up to 14x channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplication: Switch to 0V, Switch to VBatt, logic signal, Magnetic or Hall effect frequency based signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -20.0V\u003c\/li\u003e\n\u003cli\u003eInput Frequency Range: 0 - 30kHz (Available on DI 1- 8)\u003c\/li\u003e\n\u003cli\u003eFilter time constant = 12us\u003c\/li\u003e\n\u003cli\u003eInput Impedance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   DI 1- 8:  39k Ohms to ground.\u003c\/p\u003e\n\u003cp\u003eo   DI 9 -14: 70k Ohms to ground.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitchable Pull-up resistor on all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo    4k7 to 9.0V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eIndependent programmable arming thresholds from 0.1V to 15.0V on frequency based inputs. Resolution = 0.1V.\u003c\/li\u003e\n\u003cli\u003eProgrammable trigger edge(s).\u003c\/li\u003e\n\u003cli\u003eMaximum input signal amplitude \/-100V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Input Mode\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhen not used as frequency or switched inputs these channels can be used to measure analog signals. All Channels have over voltage protection.\u003c\/p\u003e\n\u003cp\u003e           \u003c\/p\u003e\n\u003cp\u003eDI 1- 8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e4.88mV resolution (10 bit effective resolution)\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 39k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDI 9- 14\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e20.0mV resolution\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 70k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569248\"\u003e\u003c\/a\u003e5.0 Auxiliary Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ECU contains 3 different types of auxiliary outputs. These drives are suitable for controlling relays, resistive and inductive loads, stepper motors, DC servo motors and electronic throttles.   Auxiliary channels 1-8  can be selected as Low or High Side Control on most models.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLow Side Driver - Up to 16x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-4:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 3A\u003c\/p\u003e\n\u003cp\u003eo    Modulated peak current 5A\u003c\/p\u003e\n\u003cp\u003eo   8A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 5-8:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 2A\u003c\/p\u003e\n\u003cp\u003eo   Modulated peak current 3.5A\u003c\/p\u003e\n\u003cp\u003eo   5A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 9-12: Half bride (see below)\u003c\/li\u003e\n\u003cli\u003eAuxiliary 13-14: Sink Continuous current 6A, 12A Limit\u003c\/li\u003e\n\u003cli\u003eAuxiliary 15-16: Sink Continuous current 10A, 20A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHigh Side Driver - Up to 8x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-8: Source Continuous current 4A, 9A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHalf Bridge Driver - 4x Channels (Aux 9 - 12)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSink or Source Continuous current 5A, 8A Limit.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp. Battery voltage through Aux 9-12 Supply pin.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569249\"\u003e\u003c\/a\u003e6.0 Analog Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll analog inputs are sampled using 12bit ADCs. They are suitable for sensors that have an output voltage, potentiometers and temperature sensors. All analog inputs can also be used as switched inputs with activation levels programmable from 0 - 5V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Inputs - Up to 14x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Temperature Inputs - Available on 6 channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable pull-up control on Analog Channels 7 -12\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e1.0k ohm input resistance to 5.0V and 100k Ohms to 0V\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569250\"\u003e\u003c\/a\u003e7.0 Crank and Cam Sensor Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo Independent channels with Magnetic, Hall effect and Logic options\u003c\/li\u003e\n\u003cli\u003eMaximum signal amplitude \/-100V\u003c\/li\u003e\n\u003cli\u003eInput Resistance = 39k Ohms to ground\u003c\/li\u003e\n\u003cli\u003eSwitchable Pull-up resistor = 4k7 Ohm to 5.0 V\u003c\/li\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eProgrammable Independent arming thresholds from 0.1V to 15.0V on all signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569251\"\u003e\u003c\/a\u003e8.0 Knock Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Independent channels.\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Digital Knock Integrated Circuit Technology\u003c\/li\u003e\n\u003cli\u003eSelectable Frequency from  5 - 15kHz\u003c\/li\u003e\n\u003cli\u003eSelectable Bandwidth form 300Hz - 5kHz\u003c\/li\u003e\n\u003cli\u003eProgrammable digital filter coefficients.\u003c\/li\u003e\n\u003cli\u003eSelectable gain control.\u003c\/li\u003e\n\u003cli\u003eBank selectable Knock Control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569252\"\u003e\u003c\/a\u003e9.0 Lambda Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 independent channels supporting Bosch LSU4.9 sensors\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Integrated circuit technology for sensor control.\u003c\/li\u003e\n\u003cli\u003eClosed Loop heater temperature control for precise lambda measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569253\"\u003e\u003c\/a\u003e10.0 Analog Voltage Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResolution is 4.88mV (10 bit)\u003c\/li\u003e\n\u003cli\u003eOutput voltage range 0 - 5.0V\u003c\/li\u003e\n\u003cli\u003eOutput driving current 100mA\u003c\/li\u003e\n\u003cli\u003eOutput impedance 22 Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569254\"\u003e\u003c\/a\u003e11.0 Voltage Supply Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Engine Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Auxiliary Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e8V CAS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.4 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569255\"\u003e\u003c\/a\u003e12.0 Voltage Supply Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eECU Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain ECU Power Supply\u003c\/li\u003e\n\u003cli\u003ePower Supply for Auxiliary Channels 1- 8 High Side Drivers\u003c\/li\u003e\n\u003cli\u003eOperating Range 6.0V - 22.0V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAux 9-12 Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply for Auxiliary 9-12 Half Bridge Drivers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Connect to ECU Power Supply in non DBW applications\u003c\/p\u003e\n\u003cp\u003eo   Connect to DBW Relay output in DBW applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFlyback Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback supply for Injector Channels when Peak \u0026amp; Hold mode is active\u003c\/li\u003e\n\u003cli\u003eFlyback supply for Auxiliary Channels.\u003c\/li\u003e\n\u003cli\u003eConnection will depend on loom layout. In most cases connect to a Battery Constant supply to prevent back-feeding issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569256\"\u003e\u003c\/a\u003e13.0 Dedicated Functions\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Main Relay Control\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a relay ground, 100mA Limit\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Ignition Switch\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsed to control Main EFI Relay circuit at key-on\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003eAdjustable ON\/OFF thresholds. Resolution = 0.1V.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":43743663751365,"sku":"45985674920253","price":4940.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/KV8KEYPAD.jpg?v=1718845826"},{"product_id":"emtron-kv16-copy","title":"EMTRON KV16 AND 8 BUTTON KEYPAD","description":"\u003cp\u003e\u003cspan\u003eEmtron’s KV16 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 16 Channels of Fuel (8 cylinders fully sequential staged injection) and 12 Channels fully sequential Ignition.  Every KV16 is housed in a durable billet Aluminium enclosure and includes up to 32MB permanent memory for on board logging, 4-channel oscilloscope function, DBW control up to 4 channels, dual LSU4.9 Lambda controllers, dual digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003ePower Supply\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/li\u003e\n\u003cli\u003eOperating current: 400mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse battery protection via external fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” battery transient protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Temperature\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMax operating range: -30 to 110°C (-22 to 230°F)\u003c\/li\u003e\n\u003cli\u003eRecommended operating range: -30 to 85°C (-22 to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAluminium 6061 grade CNC billet enclosure\u003c\/li\u003e\n\u003cli\u003eEnclosure size 134 mm x 162 mm x 27 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 740g\u003c\/li\u003e\n\u003cli\u003eConnector system: 120-way Super Seal waterproof connectors with gold plated contacts, pin diameter of 1 mm\u003c\/li\u003e\n\u003cli\u003eCurrent rating: maximum 15A per pin (wire gauge dependant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInternal\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual 100MHz processors\u003c\/li\u003e\n\u003cli\u003e500Mb DDR RAM\u003c\/li\u003e\n\u003cli\u003e32MB ECU logging memory, over 1200 channels available,  1Hz to 500Hz logging rate\u003c\/li\u003e\n\u003cli\u003e4-Channel oscilloscope function\n\u003cul\u003e\n\u003cli\u003eSampling at 100k samples\/second\u003c\/li\u003e\n\u003cli\u003eIncludes Crank and Cam sensor inputs\u003c\/li\u003e\n\u003cli\u003eIncludes Digital inputs 1-4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn-Board barometric pressure sensor, range 40 – 115.0 kPa\u003c\/li\u003e\n\u003cli\u003e3-Axis accelerometer, 16-Bit resolution, \u003cu\u003e+\u003c\/u\u003e2g\/\u003cu\u003e+\u003c\/u\u003e4g\/\u003cu\u003e+\u003c\/u\u003e8g dynamically selectable full-scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x High Speed Ethernet 100Mbps for tuning software connection\u003c\/li\u003e\n\u003cli\u003e2x CAN 2.0B 1Mbps\/ 6 Channels per node, total 128 messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":43743893881029,"sku":"45985864319293","price":6150.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/KV16KEYPAD.jpg?v=1718846597"},{"product_id":"emtron-kv12-and-8-button-keypad","title":"EMTRON KV12 AND 8 BUTTON KEYPAD","description":"\u003cp\u003e\u003ca href=\"https:\/\/emtronaustralia.com.au\/Files\/?dfilename=KV12++ECU+Data+Sheet+.pdf\" title=\"KV12 ECU Data Sheet\"\u003eKV12 ECU Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEmtron’s KV12 is a wire in ECU with extreme flexibility.  Industry leading I\/O count will ensure you do not have to make any sacrifices when configuring your engine and vehicle.  This ECU will support up to 12 Channels of Fuel (6 cylinders fully sequential staged injection) and 12 Channels fully sequential Ignition. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Every KV12 is housed in a durable billet Aluminium enclosure and includes up to 64Mb permanent memory for on board logging and oscilloscope function, twin DBW control, twin Lambda controllers, twin digital Knock control, Ethernet communications and 3 axis G-force sensing to name a few.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e1.0 General\u003c\/h1\u003e\n\u003ch2\u003e \u003cstrong\u003ePower Supply\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eOperating Voltage: 6.0 to 22.0 Volts DC (ECU shutdowns at 24.0V)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Current: 350mA at 14.0V (excluding sensor and load currents)\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection via External Fuse\u003c\/li\u003e\n\u003cli\u003e“Smart” Battery Transient Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eECU Internal Temperature Operating Range: -30 to 110°C (-22 to 230°F)\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e Physical\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eExternal:\u003c\/h2\u003e\n\u003cp\u003eEnclosure Size: 134 mm x 162 mm x 27 mm\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight KV Series: 0.74kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInternal:\u003c\/h2\u003e\n\u003cp\u003eDual 100MHz Processors\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500MB DDR RAM  (0.5GB)\u003c\/li\u003e\n\u003cli\u003eUp to 64MB permanent memory storage for ECU logging and Oscilloscope Function\u003c\/li\u003e\n\u003cli\u003eUp to x10 channel Oscilloscope function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Sampling at 500k samples\/second\u003c\/p\u003e\n\u003cp\u003eo   Includes Crank and Cam sensors inputs\u003c\/p\u003e\n\u003cp\u003eo   Includes Digital Inputs 1-8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-Board Barometric Pressure Sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Range 40 - 115.0 kPa\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Axis Accelerometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   16 Bit Resolution\u003c\/p\u003e\n\u003cp\u003eo   2g\/ 4g\/ 8g dynamically selectable full-scale\u003c\/p\u003e\n\u003cp\u003eo   Output Data Rate 500Hz\u003c\/p\u003e\n\u003cp\u003eCommunications\u003c\/p\u003e\n\u003cp\u003eEthernet 100Mbps. High Speed communications channels used for tuning and uploading ECU log files.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x CAN nodes\/ 6 Channels per node\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569245\"\u003e\u003c\/a\u003e2.0 Injection\u003c\/h1\u003e\n\u003cp\u003eThe ECU can control both modes of injection: Saturated and Peak \u0026amp; Hold.\u003c\/p\u003e\n\u003cp\u003ePeak and Hold - 12 x channels \u003c\/p\u003e\n\u003cp\u003eWhen using low impedance injectors (\u0026lt; 5 Ohms) the ECU uses a switch mode current limiting technique to minimise heat dissipation in the Injector. This gives better injector control and helps maximize injector life by lower its operating temperature.\u003c\/p\u003e\n\u003cp\u003eIndependently configurable Peak and Hold currents up to 12 cylinders\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Peak current 8A\u003c\/li\u003e\n\u003cli\u003eMax Hold current 2A\u003c\/li\u003e\n\u003cli\u003eCurrent limited to 10A.\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSaturated\u003c\/p\u003e\n\u003cp\u003eRequired when injector resistance is greater than 5 Ohms.\u003c\/p\u003e\n\u003cp\u003eCurrent limited to 5A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback Voltage Clamp: 60V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eAuxiliary Fuel Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Fuel channels can be used to switch or modulate resistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 5A, current limit 8A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 60V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca name=\"_Toc356569246\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1\u003e3.0 Ignition\u003c\/h1\u003e\n\u003cp\u003eIgnition Control - 12x channels\u003c\/p\u003e\n\u003cp\u003e12 Channels Sequential\/Wasted Ignition or 6  Leading\/6 Trailing Ignition.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent switchable pull-up resistor control on channels 1 to 12.\u003c\/li\u003e\n\u003cli\u003eAdjustable source current;  35mA at 5V or  70mA  at 8.2V for high current mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAuxiliary Ignition Mode\u003c\/p\u003e\n\u003cp\u003eUnassigned Ignition channels can be used to switch or modulate\u003c\/p\u003e\n\u003cp\u003eresistive and inductive loads.\u003c\/p\u003e\n\u003cp\u003eSink continuous current 1A, current limit 3.0A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback voltage clamp: 40V.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 5kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569247\"\u003e\u003c\/a\u003e4.0 Digital Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDigital Inputs Overview - Up to 14x channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplication: Switch to 0V, Switch to VBatt, logic signal, Magnetic or Hall effect frequency based signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -20.0V\u003c\/li\u003e\n\u003cli\u003eInput Frequency Range: 0 - 30kHz (Available on DI 1- 8)\u003c\/li\u003e\n\u003cli\u003eFilter time constant = 12us\u003c\/li\u003e\n\u003cli\u003eInput Impedance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   DI 1- 8:  39k Ohms to ground.\u003c\/p\u003e\n\u003cp\u003eo   DI 9 -14: 70k Ohms to ground.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitchable Pull-up resistor on all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo    4k7 to 9.0V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eIndependent programmable arming thresholds from 0.1V to 15.0V on frequency based inputs. Resolution = 0.1V.\u003c\/li\u003e\n\u003cli\u003eProgrammable trigger edge(s).\u003c\/li\u003e\n\u003cli\u003eMaximum input signal amplitude \/-100V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Input Mode\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhen not used as frequency or switched inputs these channels can be used to measure analog signals. All Channels have over voltage protection.\u003c\/p\u003e\n\u003cp\u003e           \u003c\/p\u003e\n\u003cp\u003eDI 1- 8\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e4.88mV resolution (10 bit effective resolution)\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 39k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDI 9- 14\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e20.0mV resolution\u003c\/li\u003e\n\u003cli\u003eMaximum usable Analog Input Voltage: 20.0V\u003c\/li\u003e\n\u003cli\u003eInput Impedance = 70k Ohms to ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569248\"\u003e\u003c\/a\u003e5.0 Auxiliary Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ECU contains 3 different types of auxiliary outputs. These drives are suitable for controlling relays, resistive and inductive loads, stepper motors, DC servo motors and electronic throttles.   Auxiliary channels 1-8  can be selected as Low or High Side Control on most models.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLow Side Driver - Up to 16x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-4:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 3A\u003c\/p\u003e\n\u003cp\u003eo    Modulated peak current 5A\u003c\/p\u003e\n\u003cp\u003eo   8A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 5-8:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Continuous current 2A\u003c\/p\u003e\n\u003cp\u003eo   Modulated peak current 3.5A\u003c\/p\u003e\n\u003cp\u003eo   5A Limit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 9-12: Half bride (see below)\u003c\/li\u003e\n\u003cli\u003eAuxiliary 13-14: Sink Continuous current 6A, 12A Limit\u003c\/li\u003e\n\u003cli\u003eAuxiliary 15-16: Sink Continuous current 10A, 20A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHigh Side Driver - Up to 8x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary 1-8: Source Continuous current 4A, 9A Limit\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection\/Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp: Dependent on Flyback pin configuration. Normally battery constant power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHalf Bridge Driver - 4x Channels (Aux 9 - 12)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSink or Source Continuous current 5A, 8A Limit.\u003c\/li\u003e\n\u003cli\u003eMaximum Frequency: 15kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOver current \/ Short to Battery protection Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge (ESD) protection\u003c\/li\u003e\n\u003cli\u003eReverse Battery Protection\u003c\/li\u003e\n\u003cli\u003eFlyback Voltage Clamp. Battery voltage through Aux 9-12 Supply pin.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569249\"\u003e\u003c\/a\u003e6.0 Analog Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll analog inputs are sampled using 12bit ADCs. They are suitable for sensors that have an output voltage, potentiometers and temperature sensors. All analog inputs can also be used as switched inputs with activation levels programmable from 0 - 5V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Voltage Inputs - Up to 14x Channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAnalog Temperature Inputs - Available on 6 channels\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable pull-up control on Analog Channels 7 -12\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 -5.0V\u003c\/li\u003e\n\u003cli\u003e1.0k ohm input resistance to 5.0V and 100k Ohms to 0V\u003c\/li\u003e\n\u003cli\u003e1st order 100Hz Low pass filter.\u003c\/li\u003e\n\u003cli\u003e1.22 mV resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569250\"\u003e\u003c\/a\u003e7.0 Crank and Cam Sensor Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo Independent channels with Magnetic, Hall effect and Logic options\u003c\/li\u003e\n\u003cli\u003eMaximum signal amplitude \/-100V\u003c\/li\u003e\n\u003cli\u003eInput Resistance = 39k Ohms to ground\u003c\/li\u003e\n\u003cli\u003eSwitchable Pull-up resistor = 4k7 Ohm to 5.0 V\u003c\/li\u003e\n\u003cli\u003e“True” Zero crossing detection on magnetic based signals\u003c\/li\u003e\n\u003cli\u003eProgrammable Independent arming thresholds from 0.1V to 15.0V on all signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569251\"\u003e\u003c\/a\u003e8.0 Knock Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Independent channels.\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Digital Knock Integrated Circuit Technology\u003c\/li\u003e\n\u003cli\u003eSelectable Frequency from  5 - 15kHz\u003c\/li\u003e\n\u003cli\u003eSelectable Bandwidth form 300Hz - 5kHz\u003c\/li\u003e\n\u003cli\u003eProgrammable digital filter coefficients.\u003c\/li\u003e\n\u003cli\u003eSelectable gain control.\u003c\/li\u003e\n\u003cli\u003eBank selectable Knock Control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569252\"\u003e\u003c\/a\u003e9.0 Lambda Control\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 independent channels supporting Bosch LSU4.9 sensors\u003c\/li\u003e\n\u003cli\u003eUsing Bosch, Integrated circuit technology for sensor control.\u003c\/li\u003e\n\u003cli\u003eClosed Loop heater temperature control for precise lambda measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569253\"\u003e\u003c\/a\u003e10.0 Analog Voltage Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResolution is 4.88mV (10 bit)\u003c\/li\u003e\n\u003cli\u003eOutput voltage range 0 - 5.0V\u003c\/li\u003e\n\u003cli\u003eOutput driving current 100mA\u003c\/li\u003e\n\u003cli\u003eOutput impedance 22 Ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569254\"\u003e\u003c\/a\u003e11.0 Voltage Supply Outputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Engine Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5V Auxiliary Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.25 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e8V CAS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous current: 0.4 Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy: \/- 0.5% at 20 °C\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569255\"\u003e\u003c\/a\u003e12.0 Voltage Supply Inputs\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eECU Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain ECU Power Supply\u003c\/li\u003e\n\u003cli\u003ePower Supply for Auxiliary Channels 1- 8 High Side Drivers\u003c\/li\u003e\n\u003cli\u003eOperating Range 6.0V - 22.0V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAux 9-12 Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply for Auxiliary 9-12 Half Bridge Drivers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eo   Connect to ECU Power Supply in non DBW applications\u003c\/p\u003e\n\u003cp\u003eo   Connect to DBW Relay output in DBW applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFlyback Supply\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlyback supply for Injector Channels when Peak \u0026amp; Hold mode is active\u003c\/li\u003e\n\u003cli\u003eFlyback supply for Auxiliary Channels.\u003c\/li\u003e\n\u003cli\u003eConnection will depend on loom layout. In most cases connect to a Battery Constant supply to prevent back-feeding issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\n\u003ca name=\"_Toc356569256\"\u003e\u003c\/a\u003e13.0 Dedicated Functions\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Main Relay Control\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a relay ground, 100mA Limit\u003c\/li\u003e\n\u003cli\u003eShort circuit, Thermal overload protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDedicated Ignition Switch\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsed to control Main EFI Relay circuit at key-on\u003c\/li\u003e\n\u003cli\u003eInput Analog Voltage Range: 0 - 20.0V\u003c\/li\u003e\n\u003cli\u003e100k ohms input resistance to ground\u003c\/li\u003e\n\u003cli\u003eAdjustable ON\/OFF thresholds. Resolution = 0.1V.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":43743924060357,"sku":"45985957085501","price":5490.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/KV12KEYPAD.jpg?v=1718846760"},{"product_id":"emtron-shadow-8","title":"EMTRON SHADOW 8","description":"\u003cp\u003e\u003cspan\u003eEmtron’s Shadow 8 is a wire in ECU with a high level of flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cem\u003e\u003cstrong\u003eTHE NEW \"BEST BANG FOR BUCK\" IS NEARLY HERE!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis ECU will support up to 8 Channels of fully sequential Fuel and Ignition.  Every unit is housed in a durable billet Aluminium enclosure and includes 16MB permanent memory for on-board logging, DBW control, USB C Communications and Knock control up to 2 channels to name a few.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRE-ORDER YOURS NOW\u003c\/strong\u003e\u003c\/p\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":44240957014213,"sku":"1908-082","price":2145.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/Shadow8_Rendering_Angle.webp?v=1732150630"},{"product_id":"evo-x-to-emtron-kv8-kit","title":"EVO X to Emtron KV8 Kit","description":"\u003cp\u003eThe Mitsubishi EVOX to Emtron KV8 kit allows you to take advantage of the Emtron motorsports features and functions while allowing full OE CAN Bus integration.\u003c\/p\u003e\n\u003cp\u003eThe Kit Includes:\u003c\/p\u003e\n\u003cp\u003eEmtron KV8\u003cbr\u003eMitsubishi EVO X to KV Mounting Kit\u003cbr\u003eMitsubishi EVO X to KV Patch Harness\u003cbr\u003eMitsubishi EVO X Application Build\u003cbr\u003eEmtron Tuning Cable\u003cbr\u003e*If you wish to include lambda control you will require an A connector and LSU4.9 sensor.\u003c\/p\u003e\n\u003cp\u003e**Manual Transmission Models only**\u003c\/p\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":44269788594373,"sku":"45857758773565","price":6600.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/evox-scaled.webp?v=1733195913"},{"product_id":"emtron-kv8-and-install-kit","title":"Emtron KV8 and Install Kit","description":"\u003cp\u003e\u003cspan\u003eThis package is ideal for those building a new harness or re-pinning a new harness to suit the Emtron ECU.  The Kit includes an Emtron KV8, ABCD Plug and Pin Kit, Tuning Cable and Billet KV Mount.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":45129486762181,"sku":null,"price":4785.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/rn-image_picker_lib_temp_aa0a746b-0b1a-4bca-973b-cf3ca53c03ea.jpg?v=1758705021"},{"product_id":"emtron-kv12-and-install-kit","title":"Emtron KV12 and Install Kit","description":"\u003cp\u003e\u003cspan\u003eThis package is ideal for those building a new harness or re-pinning a new harness to suit the Emtron ECU.  The Kit includes an Emtron KV12, ABCD Plug and Pin Kit, Tuning Cable and Billet KV Mount.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":45129491251397,"sku":null,"price":5335.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/rn-image_picker_lib_temp_30b11d33-28fd-48c9-8cfd-176581915e2d.jpg?v=1758705156"},{"product_id":"emtron-kv12-and-install-kit-1","title":"Emtron KV12 and Install Kit","description":"\u003cp\u003e\u003cspan\u003eThis package is ideal for those building a new harness or re-pinning a new harness to suit the Emtron ECU.  The Kit includes an Emtron KV12, ABCD Plug and Pin Kit, Tuning Cable and Billet KV Mount.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Emtron","offers":[{"title":"Default Title","offer_id":45129491415237,"sku":null,"price":5335.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/5397\/files\/rn-image_picker_lib_temp_30b11d33-28fd-48c9-8cfd-176581915e2d.jpg?v=1758705156"}],"url":"https:\/\/quickbitz.com.au\/collections\/emtron-ecus.oembed?page=2","provider":"Quickbitz","version":"1.0","type":"link"}